欢迎您访问武汉艾美捷科技有限公司官方网站!
站点地图 服务热线:400-6800-868
  • 产品
  • 文章

PRODUCT CENTER

细胞分析试剂盒
产品中心

当前位置:首页 > 产品中心 > 细胞生物学产品 > 细胞分析试剂盒

中文名称

Formaldehyde Assay Kit, BioAssay

英文名字
Formaldehyde Assay Kit, BioAssay
供应商
USBiological
产品货号
F6000-03
产品报价
¥1/96Tests
产品说明书
点击查看
购买方式
银行转账、电汇、支票、现金,在线支付宝及网银支付,或直接与我们电话联系400-6800-868
产品新闻
背景资料
USBiological品牌是全球有名的抗原抗体和生化试剂供应商,生产世界上种类最多的抗体,用于Western Blot、免疫沉淀、免疫荧光、免疫组化和流式细胞术等多种检测方法。武汉艾美捷科技作为USBiological品牌中国区域总代理,是行业中少有的致力于服务客户,帮助客户,且拥有独立的专业销售团队、技术支持团队、市场营销团队、进出口报关团队的高科技生物企业。可以为您提供及时的咨询响应,专业的产品和解决方案支持,稳健快捷的交货周期,优质放心的售后服务。我们致力于为您提供有价值的产品和服务,在意您的成功!
产品描述
Introduction:Formaldehyde (Methanal) is the simplest aldehyde. It is widely employed in industry for a wide range of applications. Formaldehyde is also used as a disinfectant and is a commonly utilized tissue fixative and embalming agent. Formaldehyde is naturally present in all tissues and body fluids. Recently it has been shown that some cancer types exhibit elevated formaldehyde levels. Increased formaldehyde concentration in urine has been associated with prostate and bladder cancer. Thus, measuring formaldehyde in urine can be a very useful tool when studying cancer. This Formaldehyde Assay Kit provides a convenient fluorimetric means to measure formaldehyde in biological samples. In the assay, formaldehyde is derivatized with acetoacetanilide in the presence of ammonia. The resulting fluorescent product is then quantified fluorimetrically excitation/emission wavelength: 370/470nm). The assay is simple, sensitive, stable and high-throughput adaptable. The assay can detect as low as 1.5uM formaldehyde in biological samples.Key Features:Safe: Non-radioactive assaySensitive and accurate: As low as 1.5uM (45ppb) formaldehyde can be quantified.Homogenous and convenient: Mix-incubate-measure type assay. No wash and reagent transfer steps are involved. Robust and amenable to HTS: Can be readily automated on HTS liquid handling systems for processing thousands of samples per day. Applications:Formaldehyde determination in urine and other biological samples.Kit Contents:F6000-03A: Reagent A, 1x5mlF6000-03B: Reagent B, 1x3mlF6000-03C: Formaldehyde Standard, 1x100ulF6000-03D: 10% TCA, 1x5mlF6000-03E: Neutralizer, 2 x 1.5mlStorage and Stability:The kit is shipped at room temperature. Store all reagents at 4°C. Shelf life of 12 months after receipt.Materials Required But Not Provided:Pipeting devicesCentrifuge tubesBlack flat bottom 96-well plates (e.g., Corning Costar)Plate readerPrecautions:Reagents are for research use only. Normal precautions for laboratory reagents should be exercised while using the reagents. Please refer to Material Safety Data Sheet for detailed information. Assay Procedure:Note: Use black flat-bottom plates. Prior to assay, bring all reagents to room temperature. 1. StandardsMix 5ul of the provided formaldehyde standad with 495ul dH2O to make a 100uM Premix. Dilute standard as follows:No.Premix + H2OFormaldehyde (uM)1100ul + 0ul1002 60ul + 40ul 603 30ul + 70ul 304 0ul + 100ul 0Transfer 50ul standards into separate wells of the plate.2. Sample PreparationUrine samples should be diluted 2.5-fold with dH2O. If urine samples contain visible particulates, then the samples should be cleared by either filtration or centrifugation (14,000 rpm, 5 min.).Samples high in protein (cell lysate, serum, etc.) need to be deproteinated and neutralized prior to assaying. To deproteinate, add 50ul 10% TCA per 100ul sample. Vortex and centrifuge for 5 min at 14,000 rpm. Transfer 100ul of clear supernatant to a clean tube and neutralize with 25ul Neutralizer. Note: Measured ∆RFU’s for deproteinated samples need to be multiplied by 1.875 to compensate for the resulting dilution of the sample. Samples not measured the same day should be stored frozen, preferably at -80°C. 3. Add 50ul of each prepared sample to two separate wells of the plate (one well will be used as a Sample Blank). 4. Prepare Working Reagent for each standard and sample well by mixing 33ul Reagent A and 22ul Reagent B. For the Sample Blanks, make the following Working Reagent: 33ul Reagent A + 22ul dH2O. Add 50ul of the appropriate Working Reagent to each well. Tap plate to mix. Incubate at room temperature for 30 min protected from light. 5. Read fluorescence intensity using 370nm excitation wavelength and 470nm emission wavelength.Calculations:Plot the RFU measured at 30 min for each standard against the standard concentrations. Determine the slope using linear regression fitting. The formaldehyde concentration of a sample is calculated as follows:[Formaldehyde] = [(RFU sample - RFU blank - RFU water)/Slope] x nwhere:RFU sample, RFU blank and RFU water are the measured fluorescence values of the sample, sample blank and water, respectivelySlope is the slope of the standard curve in uM-1n is the dilution factor (n= 1.875 for deproteinated samples).The calculated concentration is expressed in uM unit.Note: If the sample formaldehyde concentration is higher than the 100uM prior to applying the dilution factor, dilute sample in water and repeat the assay. Multiply result by the dilution factor. Conversion Factor: 1uM formaldehyde is equivalent to 300 ppb.
产品特点
针对Formaldehyde Assay Kit, BioAssay该产品的特点优势,欢迎查阅官网提供的产品说明书。
保存建议
建议收到Formaldehyde Assay Kit, BioAssay产品后将其置于RT/4°C保存。
其他
Usbiological公司是美国著名的抗体和生化试剂供应商,生产世界上种类最多的抗体,用于Western Blot、免疫沉淀、免疫荧光、免疫组化和流式细胞术等多种检测方法。Usbiological公司现已拥有超过50,19234种抗体、抗原和生化产品,为科研用户提供了诸多超值选择。
注意
该页面的中文产品信息的翻译,仅供参考。准确的产品信息请以厂家的英文说明书为准。下单前,请浏览说明书确认。
在线留言
  • 高品质保障 成熟的生产研发技术
  • 高性价比 价宜质优,性价比高
  • 高效省心 从购买到使用,放心无忧
  • 安全运输 完善的保护措施安全运输

微信扫码在线客服

微信咨询

全国免费技术支持

400-6800-868

在线客服